FTE5000 Loss Test Set with ORL and Video Probe

The FTE-5000 combines four functions for testing optical networks together in one unit. It brings together a -55dB ORL meter, power meter, laser source and video scope capability with IEC61300-3-35 method “B” Pass/Fail End face Grading Map (probe sold separately).

The FTE-5000 is a full featured ORL Loss Test Set. It has 4” super bright color touch screen display with large easy to read characters. It performs optical return loss measurements to -55db at up to three wavelengths and is an automated loss test set with dual or triple wave Light sources. The power meter uses an InGaAs detector which is calibrated at 850, 1300, 1310, 1490, 1550 and 1625nm, with a dynamic range of -77dBm.

These units are available in single, dual, triple or quad wavelength configurations and display measurements up to three wavelengths at one time. In the Autotest mode, the master unit changes wavelengths at a fixed rate and informs the slave unit of the wavelength currently being measured. Use this method to test up to three wavelengths at a time and store the loss measurements for each of the lasers fired during the test. Up to 5000 tests may be stored and recalled via the unit’s USB port. Use TTI’s CertSoft PC application software for downloading stored data and organizing the information or use the Android Bluetooth virtual instrument application for remote operation.

The information from an OTDR, LTS, ORL and video scope may be combined to offer a comprehensive report for all of your network testing needs.

The FTE-5000 also includes a video scope (probe sold separately). Use the video scope to ensure the integrity and cleanliness of the connectors being tested.

Use the modulation feature to perform fiber identification function. The power meter will identify modulated signals at 270, 1000 and 2000 Hz produced a modulate light source.

Features
Optical Loss/ORL Tester
ORL Measurement Range to -55 dB
PM with -77 dBm Dynamic Range
IEC61300-3-35 Method “B” Video Scope (Probe Sold Separately)
Auto Test Up to Three Wavelengths
Automated Loss Measurements
Auto Wavelength Switching
Universal PM and LS Adapters
Storage for 5,000 Tests
Bright Color Display
Rechargeable NiMH Batteries
USB Interface
Free Report Software
On-Board Help Feature
Ordering Information
FTE-5000-8513 LTS with 850/1300nm Light Source and Video Scope
(Probe Sold Separately)
FTE-5000-1315 LTS with 1310/1550nm Light Source and Video Scope
(Probe Sold Separately)
FTE-5000-345 LTS with 1310/1490/1550nm Light Source and Video Scope
(Probe Sold Separately)
FTE-5000-QUAD LTS with 850/1300/1310/1550nm Light Source
(No Video Scope Capability)
VIS-300 Video Probe for use with FTE-7000, FTE-1700 and FTE-5000 series
General Specifications
Display 4" Color TFT
Storage Locations 5,000
Battery / Operating Time 4 AA Rechargeable NiMH / 6 hrs
Power Requirements Wall Mount, Universal 100-240V 47-63 Hz 9 VDC Center Positive with US, UK, Continental Europe and Australian Plugs
Operating Temperature Range -10° to 45°C
Dimensions (w/out Rubber Boot) 7.62” L x 3.88” W x 1.56” H
(194mm L x 99mm W x 40mm H)
Weight 0.52 Kg
Accessories Provided FC, ST, SC Adaptors for both Power Meter and Light Source, Rubber Boot, Battery, Power Supply/Charger, Manual and Software on CD, USB cable

 

Power Meter Specifications
Detector Type InGaAs
Connector Type 2.5mm Interchangeable
Dynamic Range +5 to -77dB (CATV - +25 to -57dB)
Auto Test Range 0 to -40dB
Calibrated Wavelengths 850, 1300, 1310, 1490, 1550, 1625nm
Units of Measurement dBm, dB, mW, µW and nW
Power Measurement Uncertainty ± 0.18 dB under reference conditions
± 0.25 dB from 0 to -65 dBm
± 0.35 dB from 0 to +5 dBm and from -65 to -77 dBm
Resolution .01 dB
Modulation Modes Detected CW, 270 Hz, 1000 Hz, 2000 Hz

 

Light Source Specifications
Fiber Type Single Mode, Multimode
Wavelengths Available 850, 1300, 1310, 1490, 1550 and 1625 nm ±20nm as Unit is Equipped
Output Power 0 dBm, 1mw (-3dBm @ 1625nm)
Output Stability ± .05 dB / 24 hrs @ Constant Temperature
± .02 dB/C Temperature Coefficient
Laser Safety Classification Class I Safety Per FDA/CDRH and IEC-825-1 Regulation
Modulation Modes CW, 270 Hz, 1000 Hz, 2000 Hz
Spectral Width <3nm typ.

 

ORL Meter
Optical Return Loss Dynamic Range 0-55 dB
ORL Wavelengths SM Source Wavelengths
Optical Return Loss Accuracy ± 1dB @ -40db reflection
Resolution 0.01 dB


Request a Quote